Tile layout calculator
This tool is for a straight, axis-aligned grid. It shows the tile count along each wall, the size of the last piece, and the leftover if you centre the field.
Formula and a worked example
n = ceil((length + grout) ÷ (tile + grout))
The last piece along that side is length − (n − 1) × (tile + grout). If you centre the field, the leftover on each side is half of (length − (n × tile + (n − 1) × grout)), which is zero when the tiles and joints fill the wall exactly, and is a thin strip when they nearly fill it.
Example: 12 ft × 10 ft, 12 × 12 in tiles, 3/16 in joints. Length: n = 12, last piece 9.94 in. Width: n = 10, last piece 10.31 in. Field count 120 tiles; 132 after 10% waste. Neither end piece is a sliver, so a wall-to-wall start is reasonable. If an end piece would be under about 2 in, or under a third of the tile, it is usually better to shift the starting line.
Diagonal, herringbone, and other patterns are not drawn here. They also need a higher waste allowance than a straight grid.
Sources
- Module arithmetic: n tiles and n − 1 joints along a length. The “avoid a sliver at the wall” note is layout practice, not a code clause.
- ANSI A108.02 4.3.8.1 (running-bond / brick-joint patterns) sets minimum average joint widths when any side is greater than 15 in — 1/8 in for rectified tile and 3/16 in for calibrated tile, increased by edge warpage. That rule is explained on the grout line size page. It does not change the count formula.
Disclaimer: These tools give planning estimates only. Coverage, bag yields, joint widths, tile thickness, and waste vary by product, surface, pattern, and workmanship. Always check the label or technical data sheet for the product you buy, and follow the adopted installation standard (for example the TCNA Handbook and ANSI A108 in the US, or BS 5385 in the UK) and a qualified installer. Tile Lookup is not a contractor, retailer, or standards body, and it does not replace manufacturer instructions or a professional specification.