Grout line size

There is no single required grout-joint width for every tile. ANSI A108.02 says joints should be straight and of even width, with allowances for hand-moulded or rustic tiles. The notes below are the published limits and usual practice, not a design for your floor.

What the standards actually say

The Tile Council of North America’s grout FAQ points to ANSI A108.02 section 4.3.8: the nominal centreline of all joints should be straight and of even width, with due allowances for hand-moulded or rustic tiles. TCNA also notes that a tighter joint shows more variation from tile to tile, and that many people find a joint smaller than about three times the average facial-size variation looks irregular.

A more specific rule applies to running-bond / brick-joint patterns when any side of the tile is greater than 15 in (ANSI A108.02 4.3.8.1):

  • Rectified tile: average minimum joint 1/8 in, plus the amount of edge warpage on the longest edge.
  • Calibrated (non-rectified) tile: average minimum joint 3/16 in, plus that same edge warpage.

Rectified tile has had its edges mechanically finished for a tighter facial tolerance (ANSI A137.1). Calibrated tile is sorted to a stated caliber range and has a wider tolerance, so it usually needs a wider joint.

Usual starting widths (not a code table)

SituationOften used jointNote
Rectified tile, straight grid1/8 in (3 mm) is a common minimum in current practiceSome older maker notes still mention 1/16 in; confirm with the tile sheet.
Calibrated or pressed tile3/16 in or moreWider joints hide size variation.
Running bond, side greater than 15 inAt least the ANSI minimum aboveIncrease by measured edge warpage.
Rustic, handmade, or tumbled edgesWider than a rectified joint, often 1/4 in or moreANSI A108.02 calls for due allowance.

Joint width is measured between tile edges, not from the top of a bevel. TCNA notes that grout should not sit on a glazed bevel. For which cement grout to use at a given width, see sanded vs unsanded grout. Common spacer product sizes are listed on tile spacer sizes.

Sources

  • Tile Council of North America, “Grout” FAQ, including the ANSI A108.02 4.3.8 summary and the unsanded / sanded joint split. tcnatile.com/resource-center/faq/grout
  • ANSI A108.02 4.3.8.1, running-bond / brick-joint minimum average joints for tiles with any side greater than 15 in, as quoted in industry explainers such as the Ceramic Tile Education Foundation note on offsets and grout joints. ceramictilefoundation.org
  • ANSI A137.1 definitions of rectified and calibrated tile, as summarised in that same running-bond discussion.

Disclaimer: These tools give planning estimates only. Coverage, bag yields, joint widths, tile thickness, and waste vary by product, surface, pattern, and workmanship. Always check the label or technical data sheet for the product you buy, and follow the adopted installation standard (for example the TCNA Handbook and ANSI A108 in the US, or BS 5385 in the UK) and a qualified installer. Tile Lookup is not a contractor, retailer, or standards body, and it does not replace manufacturer instructions or a professional specification.